Image Restoration for Field Emission X-ray Source Array Based Radiographic Imaging

Kai Wang, Xi Chen, Haitao Cheng, Qinrong Qian, Xuanqin Mou

DOI:10.12059/Fully3D.2017-11-3203018

Published in: Fully3D 2017 Proceedings

Pages:656-659

Keywords:
radiography, field emission x-ray source array, image restoration, projection rebinning
Field emission x-ray source array is an emerging technology with some advantages compared with conventional xray source. In this work, a radiographic scheme based on field emission x-ray source array was proposed to study its possible application in radiation imaging. Each x-ray source in the array emits a cone beam x-ray through part of the object, and all the sources are overlapped to cover the whole object. Two x-ray source scan strategies, grouped scan strategy and simultaneous scan strategy, were studied. A projection rebinning based image restoration algorithm was introduced for the imaging schemes. Numerical simulations demonstrated that both scan strategies were effective for image restoration. Specifically, the grouped scan strategy produced fewer artifacts than the simultaneous scan strategy due to the non-overlap projections, while the simultaneous scan strategy enables faster imaging considering the inherent simultaneous data collection mode. This feasibility study illustrated that the field emission x-ray source array based radiographic scheme may offer a promising image modality.
Kai Wang
Institute of Image Processing and Pattern Recognition, Xi'an Jiaotong University, China
Qinrong Qian
Institute of Image Processing and Pattern Recognition, Xi'an Jiaotong University, China
Xi Chen
Institute of Image Processing and Pattern Recognition, Xi'an Jiaotong University, China
Xuanqin Mou
Institute of Image Processing and Pattern Recognition, Xi'an Jiaotong University, China
Haitao Cheng
Institute of Image Processing and Pattern Recognition, Xi'an Jiaotong University, China
  1. Sugie H, Tanemura M, Filip V, et al. Carbon nanotubes as electron source in an x-ray tube[J]. Applied Physics Letters, 2001, 78(17):2578-2580.
  2. Chen D, Song X, Zhang Z, et al. Transmission type flat-panel x-ray source using ZnO nanowire field emitters[J]. Applied Physics Letters, 2015, 107(24):243105.
  3. Grant E J, Posada C M, Castaño C H, et al. Electron field emission Particle-In-Cell (PIC) coupled with MCNPX simulation of a CNT-based flat-panel x-ray source[J]. Proceedings of SPIE - The International Society for Optical Engineering, 2011, 7961:796108-796108-11.
  4. Travish G. Addressable flat-panel x-ray sources for medical, security, and industrial applications[J]. Proceedings of SPIE - The International Society for Optical Engineering, 2012, 8502(7).
  5. Hendee W R, Ritenour E R, Hoffmann K R. Medical Imaging Physics, Fourth Edition[J]. Medical Physics, 2003, 30(4):730-730. 
  6. Noo F, Defrise M R. Single-slice rebinning method for helical cone-beam CT.[J]. Physics in Medicine & Biology, 1999, 44(2):561-570.
  7. Segars W P, Tsui B M, Frey E C, et al. Development of a 4-D digital mouse phantom for molecular imaging research.[J]. Molecular Imaging & Biology Mib the Official Publication of the Academy of Molecular Imaging, 2004, 6(3):149-59.
  8. Siddon R L. Fast calculation of the exact radiological path for a threedimensional CT array[J]. Medical Physics, 1985, 12(2):252-255.
  9. Sidky E Y, Kao C M, Pan X. Accurate image reconstruction from fewviews and limited-angle data in divergent-beam CT[J]. Journal of X-ray science and technology, 2006, 14(2):119-139.
  10. Kim D, Ramani S, Fessler J A. Accelerating X-ray CT ordered subsets image reconstruction with Nesterov’s first-order methods[C]//Proc. Intl. Mtg. on Fully 3D Image Recon. in Rad. and Nuc. Med. 2013: 22-5.